Gurugram, India, 122001
Tercel Lightning Protection Systems | TZ Series โ India, Asia & International Tercel LPS (Lightning Protection System) | TZ-20, TZ-40, TZ-50, TZ-63, TZ-90 Models Buy Tercel Lightning Arresters in India โ OEM & Certified Distributor Tercel Lightning Protection โ Design, Supply & Installation (Local + Export) --- Meta Description (โ 150โ160 characters) > Leading supplier & installer of Tercel lightning protection systems (TZ-series, ESE, surge protection) in India & globally. Contact for design, supply & certification. --- Keywords & Phrases to Target Tercel lightning protection Tercel TZ-20, TZ-40, TZ-50, TZ-63, TZ-90 Tercel lightning arrester India Buy Tercel Lightning Protection System Tercel LPS design & installation Tercel surge protection & earthing Tercel export / global lightning systems --- Sample SEO Content / Copy 1. Introduction / Overview Tercel is a premier brand of lightning protection systems, offering a full range of solutions including TZ series air terminals (TZ-20, TZ-40, TZ-50, TZ-63, TZ-90), surge protection devices, earthing & bonding accessories, and system design & certification services. Whether your facility is in India, the Middle East, Africa or beyond, our Tercel systems comply with IEC 62305, NFPA 780, AS/NZS 1768, and other international standards. With decades of experience, Tercel (via Tercel Australia & subsidiaries) supplies and supports lightning protection, earthing, surge protection globally. --- 2. Product Line and Models Here are some of the prominent Tercel models / components: Model / Component Key Specs & Features Use Cases / Application TZ-20 ฮT = 20 ยตs, stainless steel, protection radius ~20 m Small buildings, domestic / residential rooftops TZ-40 ฮT = 40 ยตs, higher performance, stainless steel Medium height structures TZ-50 / TZ-63 ฮT = 50 / 63 ยตs, larger protection radius Commercial, industrial buildings TZ-90 ฮT = 90 ยตs, high current capacity, heavy duty Tall towers, critical infrastructure Surge Protection & SPD SPDs for AC, DC, communication lines, protection tiers 1/2/3 Protect sensitive electronics, UPS, telecom Earthing & Accessories Conductors, clamps, earth enhancing compounds, pits, bonding To complete the lightning protection chain You can highlight which models you stock / install, their current handling, the protection radius, and compatibility with local codes (e.g. IS / IEC norms in India). --- 3. Services: Local to Global You should include sections for: Design & Consultation Risk assessment per IEC 62305 (or local equivalent), site survey, layout, modeling, drawings. Supply & Logistics Warehouse / stock details, national distribution in India, international export support, import / customs, documentation. Installation & Commissioning Certified technicians, quality checks, safety compliance, testing of continuity and earth resistance. Testing & Maintenance Periodic inspection, SPD testing, certification renewal, replacement of components, earth measurement. After-Sales Support & Warranty Spare parts, replacements, technical assistance, monitoring (optional). --- 4. Local / Regional SEO Integration To maximize your local search reach, embed location-specific microcopy. For example: > โWe are authorized distributors & installers of Tercel lightning protection systems in Delhi NCR, Gurgaon, Noida, Chennai, Bangalore, Chandigarh, Punjab, Haryana, UP & export regions. We service residential, commercial, industrial & infrastructure projects. If youโre in Gurgaon Sec 10, Manesar, Bhiwadi, Ghaziabad, Faridabad (or any nearby area), we offer on-site survey and fast installation of Tercel TZ series lightning arresters.โ Also, maintain separate service-area landing pages (e.g. โTercel lightning protection in Chennaiโ, โTercel systems Bangaloreโ) each with the same core content but localized. --- 5. Technical / Compliance Content Offer a deeper section explaining technicalities, which helps SEO (authority) and educates clients: Standard compliance: IEC 62305, NFPA 780, AS/NZS 1768 How ฮT (triggering time) affects protection Protection radius formulas, mesh method, rolling sphere method Coordination of air terminals, down conductors, equipotential bonding, SPDs, earthing Example: โWhen you use a TZ-50 on a 12 m high building, you get a protection radius of ~50 m (based on ฮT model).โ Soil resistivity, earth enhancement compounds Maintenance schedules and testing (continuity, earth resistance) --- 6. Call to Action & Contact / Lead Capture Near the bottom, include: โRequest Free Site Surveyโ โGet Price Quote for Tercel TZ model for your building / towerโ โUpload your layout / drawing for assessmentโ Display your phone, WhatsApp, email, office locations Certifications, case studies, projects --- 7. Internal / Interlinking Strategy Link from โLightning Protectionโ / โEarthingโ pages to the Tercel page, and vice versa. Cross-link related services: earthing, surge protection, DG kits (if relevant) Use schema (Product, Service, LocalBusiness) markup to help search engines. --- 8. Examples of SEO-Friendly Headings & Sub-sections โWhy Choose Tercel Lightning Protection Systems?โ โTercel vs Conventional Lightning Arresterโ โComparing Tercel Models TZ-20 through TZ-90โ โTercel Surge Protection & SPD Integrationโ โCase Study: Tercel LPS in Hyderabad / Bengaluru / NCRโ โExporting Tercel Systems โ Certifications, Logistics, Packagingโ โTercel Maintenance & Testing โ Best Practicesโ