8 / 10 mm ALUMINIUM SOLID ROUND CONDUCTOR

8 / 10 mm ROUND CONDUCTOR

FOR HORIZONTAL AIR TERMINATION NETWORK

Lightning Protection System as per IS/IEC 62305


PRODUCT DESCRIPTION

8mm and 10mm Round Conductors are used to create a Horizontal Air Termination Network (Air Terminal Grid) on RCC terraces, rooftops, industrial buildings, commercial complexes, and other structures requiring lightning protection.

The conductor network intercepts direct lightning strikes and safely distributes lightning current through the down conductor and earthing system. The air termination mesh shall be installed as per approved lightning protection drawings and designed in accordance with IS/IEC 62305 requirements.


KEY FEATURES

✔ Suitable for RCC Terrace Air Termination Network

✔ Available in 8mm and 10mm Diameter

✔ High Electrical Conductivity

✔ Excellent Corrosion Resistance

✔ Strong Mechanical Performance

✔ Long Service Life

✔ Easy Installation and Maintenance

✔ Compliant with IS/IEC 62305 Lightning Protection Standards


TECHNICAL SPECIFICATIONS

ParameterSpecification
Product TypeRound Conductor
Sizes Available8 mm / 10 mm
ApplicationHorizontal Air Termination Network
Installation AreaRCC Terrace / Roof Top
Material OptionsAluminium / Copper / GI
StandardIS/IEC 62305
Installation MethodGrid / Mesh Network
Grid SizeAs per Approved Drawing & Risk Assessment

APPLICATIONS

  • Commercial Buildings
  • Industrial Plants
  • Warehouses
  • Hospitals
  • Hotels
  • Educational Institutions
  • Data Centers
  • Telecom Buildings
  • Solar Power Plants
  • Residential Towers

TYPICAL TERRACE AIR TERMINATION GRID

  ┌─────────────────────────────┐
  │ □ □ □ □ □ □ □ □ □ □ □ □ □  │
  │ □ □ □ □ □ □ □ □ □ □ □ □ □  │
  │ □ □ □ □ □ □ □ □ □ □ □ □ □  │
  │ □ □ □ □ □ □ □ □ □ □ □ □ □  │
  └─────────────────────────────┘

Grid Size (A x B)
As per Lightning Protection Design
IS/IEC 62305 Requirements

STANDARDS COMPLIANCE

The conductor network shall comply with:

  • IS/IEC 62305 – Protection Against Lightning
  • IEC 62561 Series – Lightning Protection System Components

INSTALLATION REQUIREMENTS

  • Conductor shall be installed on RCC terrace using approved conductor saddles/supports.
  • Grid size shall be as per approved lightning protection drawings.
  • All joints and connections shall ensure electrical continuity.
  • Conductors shall be connected to down conductors and earthing system as per design requirements.
  • Installation shall comply with IS/IEC 62305 guidelines.

BENEFITS

⚡ Effective Lightning Interception

⚡ Enhanced Building Protection

⚡ Reliable Current Distribution

⚡ Long-Term Corrosion Resistance

⚡ Reduced Maintenance

⚡ Compliance with International Standards